NTP 100 — Install a B-0404-A
Safety information
Read the following safety information before installing the ONT.
Procedure
Use this procedure to install a B-0404-A.
1
2
3
4
NTP 100-2
Danger 1 — Contact the local utility company before you connect the
B-0404-A to the utilities.
Danger 2 — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the fiber optic cable.
Caution — Keep out of direct sunlight. Prolonged exposure to direct
sunlight can damage the B-0404-A.
Note — Observe the following:
The B-0404-A should be installed in accordance with the applicable
requirements of the NEC or CEC. Local authorities and practices take
precedent when there is conflict between the local standard and the
NEC or CEC.
The B-0404-A must be installed by qualified service personnel.
Ensure temperature falls within tolerances as show in section 7.6.
Prepare the cables at the site where the B-0404-A will be installed (DLP 100). Also,
locate the power source where the power converter will be installed.
Are any of the cables missing?
a
If yes, go to step 3.
b
If no, go to step 4.
Locate each missing cable and route them to the B-0404-A as per local practices.
Review the connection locations, as shown in Figure
March 2011
ONT Product Information Guide Edition 01
NTP
100-1.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a