5.1Automatic adjusting function
Real-time auto-tuning function sets the following parameters to the fixed value.
 Relevant parameters
Class No.
Attribute
1
03
B
1
08
B
1
10
B
1
11
B
1
12
B
1
13
B
6
10
B
6
49
B
The Real-time auto tuning function sets the following parameters as the gain is switched.
 Relevant parameters
Class No.
Attribute
1
14
B
1
15
B
1
16
B
1
17
B
1
18
B
1
19
B
1
20
B
1
21
B
1
22
B
1
23
B
1
24
B
1
25
B
1
26
B
1
27
B
(To be continued)
5-15
Title
Range
1st filter of velocity
0 to 5
detection
2nd filter of velocity
0 to 5
detection
Velocity feed forward
0 to 4000
gain
Velocity feed forward
1 to 6400
filter
Torque feed forward
0 to 2000
gain
Torque feed forward
1 to 6400
filter
Function expansion
-32768 to
setup
32767
Adjust/Torque
0 to 99
command attenuation
term
Title
Range
2nd gain setup
0 to 1
Mode of position
0 to 10
control switching
Delay time of position
0 to
control switching
10000
Level of position
0 to
control switching
20000
Hysteresis at position
0 to
control switching
20000
Position gain
0 to
switching time
10000
Mode of velocity
0 to 5
control switching
Delay time of velocity
0 to
control switching
10000
Level of velocity
0 to
control switching
20000
Hysteresis at velocity
0 to
control switching
20000
Mode of torque control
0 to 3
switching
Delay time of torque
0 to
control switching
10000
Level of torque control
0 to
switching
20000
Hysteresis at torque
0 to
control switching
20000
Unit
Function
-
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0.
-
0.1 %
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 1000 (100%).
0.01 ms When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0 (invalid).
0.1 %
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 1000 (100%).
0.01 ms When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 0 (invalid).
-
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to bit4=1.
-
When fixed parameter setup is valid (Pr0.02=1 to 4), set the
parameter to 15.
When Pr0.02=6, set the tenths digit to 1 and maintain the
unit digit.
Unit
Function
-
Sets to 1 if the current setting is not maintained (Pr0.02=1
to 4).
-
For the standard response mode (Pr0.02=1), set the
parameter to 0.
For high response mode 1 to 3 (Pr0.02=2 to 4), set the
parameter to 7.
0.1 ms
Sets to 10 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
0.1 ms
Sets to 10 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
0.1 ms
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
0.1 ms
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).
-
Sets to 0 if the current setting is not maintained
(Pr0.02=1 to 4).