Title
Range
1st damping
0 to 3000 0.1 Hz
frequency
1st damping filter
0 to 1500 0.1 Hz
setup
1st damping depth 0 to 1000 —
1st damping width
0 to 1000 -
setting
2nd damping
0 to 3000 0.1 Hz
frequency
2nd damping filter
0 to 1500 0.1 Hz
setup
2nd damping
0 to 1000 -
depth
2nd damping width
0 to 1000 -
setting
3rd damping
0 to 3000 0.1 Hz
frequency
3rd damping filter
0 to 1500 0.1 Hz
setup
Unit
Function
You can set up the 1st damping frequency of the damping
control which suppresses vibration at the load edge.
The driver measures vibration at load edge. Setup unit is 0.1
[Hz]
The setup frequency is 0.5 to 300.0 [Hz]. Setup of 0 to 4
becomes invalid.
If torque saturation occurs with damping frequency 1st enabled,
decrease the setup value, or if the operation is slow, increase it.
Usually set it to 0.
The maximum setup value is internally limited to the
corresponding damping frequency or 3000–damping frequency,
whichever is smaller.
Specifies a depth corresponding to the 1st damping frequency.
The depth is maximum if the setting value is 0. As the setting
value increases, the depth decreases. As the depth increases,
the damping effect increases, but the delay also increases. As
the depth decreases, the delay decreases, but the damping
effect also decreases.
Use the parameter to fine adjust the damping effect and delay.
Sets the width for the 1st damping frequency. The enabled
range of setup is between 10 to 1000 and will operate as set to
100 between the range of 0 to 9. Within the setup range, the
width will increase with the increase in the setup value,
increasing robustness against vibration fluctuation.
You can set up the 2nd damping frequency of the damping
control which suppresses vibration at the load edge.
The driver measures vibration at load edge. Setup unit is 0.1
[Hz].
The setup frequency is 0.5 to 300.0 [Hz]. Setup of 0 to 4
becomes invalid.
If torque saturation occurs with damping frequency 2nd
enabled, decrease the setup value, or if the operation is slow,
increase it. Usually set it to 0.
The maximum setup value is internally limited to the
corresponding damping frequency or 3000–damping frequency,
whichever is smaller.
Defines the depth against the 2nd damping frequency.
The depth becomes maximum when the setup value is 0. The
larger the setup value, the smaller the depth. Although the
damping effect increases as the depth becomes larger, the
delay becomes large. While the delay decreases as the depth
becomes smaller, the damping effect decreases.
Use this parameter to fine tune the damping effect and delay.
Sets the width for the 2nd damping frequency. The enabled
range of setup is between 10 to 1000 and will operate as set to
100 between the range of 0 to 9.Within the setup range, the
width will increase with the increase in the setup value,
increasing robustness against vibration fluctuation.
You can set up the 3rd damping frequency of the damping
control which suppresses vibration at the load edge. The driver
measures vibration at load edge. Setup unit is 0.1 [Hz]
The setup frequency is 0.5 to 300.0 [Hz]. Setup of 0 to 4
becomes invalid.
If torque saturation occurs with damping frequency 3rd
enabled, decrease the setup value, or if the operation is slow,
increase it. Usually set it to 0.
The maximum setup value is internally limited to the
corresponding damping frequency or 3000–damping frequency,
whichever is smaller.
Auto Tuning Functions
5-40