No. Title
96
Over-load warning
release level
97
Function expansion
setup 3
(To be continued)
Size
Unit
Range
[byte]
%
0 to 114
2
-
-2147483648
4
to
2147483647
Function/Contents
Sets the threshold value for releasing
the warning when the load factor
decreases from the state when the
overload warning is occurring.
Sets with the overload load factor.
If 0 is set, overload warning detection
is performed under conventional
conditions (85% of overload protection
level).
In addition, if other than "Pr6.96 <=
Pr6.95 < (Overload level)" is set,
overload warning detection is
performed under conventional
conditions (85% of overload protection
level).
Set various functions on a bit basis.
bit0: Enables/Disables quadrant
projection compensation function
extended.
0: Disabled
1: Enabled
* To set the compensation
amount of quadrant projection
by inversion direction when the
direction of the velocity has
changed, set Pr6.97 bit0 to 1.
bit1: Deterioration diagnosis warning
function:
0: Disabled
1: Enabled
bit2: Expansion of Allowable motor
operating range abnormal
protection:
0: Disabled
1: Enabled
bit3 to 7:
For manufacture use.
Permanently set at 0.
bit8: Extension of the subject control
mode for 607Fh/687Fh (Max
profile velocity).
0: standard specifications
(pp,hm,ip,pv)
1: expansion specification
(pp,hm,ip,pv,tq,cst)
bit9 to 31: For manufacture use.
Permanently set at 0.
bit 0 is the least significant bit.
List of Parameters
Related
Attribute
control
Reference
mode
A
All
7.3
B
All
4.5.4
5.2.15
6.2
6.8
Ether CAT
9-26

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Minas a6bfMinas a6 multi