11.1 Basic specifications
The specifications of the power supply module (PSM) are shown below.
For hardware specifications, refer to "REFERENCE SPECIFICATIONS Power supply module section
(SX-DSV03452)".
Item
Main power supply
Control power supply
Control input signal
Control output signal
Front panel
Regenerative function
Protective
Control power supply monitoring
functions
Main power supply monitoring
Regenerative monitoring
Temperature monitoring
Contactor monitoring
Self-diagnosis
(Note 1) These two main power monitoring results are not detected on the power supply module side, but the monitoring results are
notified to all connected driver modules, and combined with the conditions on the driver module side, Err13.0 / An alarm is
detected as Err13.1.
Content
3-phase, 400 V
DC 24 V
DIN1
Contactor feedback
DIN2
Regenerative resistor monitoring
1 power relay output for contactor control
2 LEDs
RDY (green)
State in which power supply is possible
ERR (red)
State with power supply module alarm/warning detection
Excess regenerative power can be consumed by installing a regenerative resistor
outside the power supply module.
Undervoltage
Overvoltage
Phase lack,
Overcurrent,
Undervoltage (Note 1)
AC interruption (Note 1)
Overload,
Rgenerative resistance temperature monitoring
Heatsink overheating,
Amospheric overheating
Contactor feedback error
Regenerative drive Tr/IC error
Thermistor failure
CPU error
Watchdog, etc.