9.1List of parameters
No. Title
98
Function expansion
setup 4
101 For manufacturer's
use
9-27
Size
Unit
Range
[byte]
-
-2147483648
4
to
2147483647
-
-
2
Function/Contents
Sets various function in bit units:
bit0-2: For manufacture use.
Permanently set at 0.
bit3:
Effective bit setting of
Multi-turn data.
0:16bit
1: 9bit
bit4 to 7:
For manufacture use.
Permanently set at 0.
bit8:
Control mode switching
function expansion
0: Conventional specification
1: hm operation expansion
specification
bit9 to 19: For manufacture use.
Please set fixed to 0
bit20:
Mechanical brake circuit
overload protection function
0: Valid1
1: Invalid
bit21 to 31: For manufacture use.
Permanently set at 0.
bit 0 is the least significant bit.
Permanently set at 0.