Universal Robots UR5 Service Manual page 66

With cb3.0/3.1/3.2 controller
Hide thumbs Also See for UR5:
Table of Contents

Advertisement

• Unscrew the motherboard by loosening the 4 x 2.5mm hex screws and the 4 x 5,5 hex
standoffs that hold the RS232 and DVI connectors
• Mount the smaller standoffs where the motherboard screws were before. Place the black
cable from the Teach Pendant and the Ethernet cable on the left side of the Standoff as
shown on the photo. Note: If your Ethernet cable has a black plug (Figure 1) at one end,
then this end must be connected to the Safety Control Board.
UR5
5. Service and Replacement of parts
60