Universal Robots UR5 Service Manual page 124

With cb3.0/3.1/3.2 controller
Hide thumbs Also See for UR5:
Table of Contents

Advertisement

C55A52
5V, 3V3 or ADC error
(5V too low)
C55A53
5V, 3V3 or ADC error
(5V too high)
C55A90
Bootloader error,
robot voltage too low
or current too high
C55A91
Bootloader error,
robot voltage too high
C55A100
Safety violation
C55A101
Safety Channel Error
in Safety Control
Board
C55A102
Safety Channel Error
in Screen
C55A103
Safety Channel Error
in Euromap67
Interface
C55A109
Received fault
message from PC
C55A110
Safety State is
changing too often
C55A111
On/Off State is
changing too often
C55A112
Robot current sensors
readings differ
C55A120
Robot current is too
high while emergency
stopped
C55A121
Robot current is too
high while safeguard
stopped
UR5
Safety Control Board
hardware fault
Safety Control Board
hardware fault
118
7. Troubleshooting
a) Do a Complete rebooting
sequence as per section
5.3.7
b) If this happens more
than two times in a row,
replace Safety Control
Board
a) Do a Complete rebooting
sequence as per section
5.3.7
b) If this happens more
than two times in a row,
replace Safety Control
Board
User Manual