Universal Robots UR5 Service Manual page 154

With cb3.0/3.1/3.2 controller
Hide thumbs Also See for UR5:
Table of Contents

Advertisement

1. Fuse 48 V:
The 5A fuse (F801) "48V" protects all 48V in the system inclusive of Euromap from over
current.
This information is only for troubleshooting. Do NOT replace the fuse under any
circumstances.
In case of failure, ONLY replace the SCB with a new tested board.
2. Fuse 24 V:
2 x 5A fuses (F1001 and F1002) in parallel protect the DI/DO 24 V supply on the Safety
Control Board, whether the 24 V is from the controller or external power supply. Do NOT
replace the fuses under any circumstances. In case of failure ONLY replace the SCB with a
new tested board.
3. LED indicators:
• 12V-PSU    On when the power plug is connected.
• 12V    System: On when the main controller power has been activated.
• 5V    On when "12V System" is on and indicates that 5V is present.
• -4V    On when "12V System" is on and indicates that – 4V to analog I/O is present.
• 3V3A
On when 5V is on and indicates 3.3V for logic Safety circuit A is present.
• 3V3B    On when 5V is on and indicates 3.3V for logic Safety circuit B is present.
• 48V
Indicates 48 V is present on the Safety Control Board
• 24V
48V is detected and ok, indicates that internal 24 V is present for I/Os
• R
48 V present on robot arm
• A
Indicates Status for Logic A: a blink sequence
• B    Indicates status for Logic B: a blink sequence  
UR5
148
7. Troubleshooting
User Manual