7. Troubleshooting
C56
Overvoltage shutdown Voltage exceeded 55V
C57
Brake release failure
C57A1
Joint did not move or
motor encoder is not
functioning
C57A2
Large movement
detected during brake
release
C57A3
Robot was not able to
brake release, see log
for details
C58
Motor encoder not
calibrated
C59
Overcurrent shutdown Overcurrent in joint.
C61
Idle power
consumption to high
C62A1
Thermal issue: Joint
temperature: High (80
C)"
User Manual
Argument = Current in Amps.
The system is drawing more
power than expected while
idle.
Argument = Watt.
Warning
119
a) Check Energy Eaters
cable and connections.
b) Check Energy
c) Replace Energy Eater
a) Check Brake, solenoid
b) Check TCP
configuration, payload and
mounting settings
a) Check Brake, solenoid
b) Check TCP
configuration, payload and
mounting settings
a) Check Brake, solenoid
b) Check TCP
configuration, payload and
mounting settings
a) Check Brake, solenoid
b) Check TCP
configuration, payload and
mounting settings
a) Check for short circuit.
b) Do a Complete rebooting
sequence as per section
5.3.7
c) If this happens more
than two times in a row,
replace joint
Try the following actions to
see which resolves the
issue:
a) Check Energy Eaters
cable and connections
b) Check Energy Eater
c) Replace Energy Eater
a) Check nothing is
hindering free movement of
the joints
b) Check TCP
configuration, payload and
mounting settings
UR5