Field
Baud Rate
Stop Bits
Parity
COM Interface Type Describes the COM interface connector.
RTS Control
DTR Control
Operational State
Passthrough State: Initiator
Field
Passthrough State
VBrick 9000 Encoder Admin Guide
Description
Rate of Passthrough port. Rate can be set to the following (Default
= 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.
Number of stop bits for Passthrough port (1 or 2).
None, Even, Odd.
• RS232 – standard RS-232 serial port connector.
• RS422/485 – RS-422/485 4-wire serial port connector.
Force Off, Force On or Automatic. If automatic, the control will be
on when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force On.
Force Off, Force On or Automatic. If automatic, the control will be
On when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force On.
Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Monitor > Monitor the
Network page. This will display "Active" if in Passthrough mode.
Description
Initiator – In this case it will continuously attempt to automatically
initiate a Passthrough connection to the remote destination. This
mode also offers metadata destination options.