VBrick 9000 Admin Manual page 149

Hide thumbs Also See for 9000:
Table of Contents

Advertisement

Field
Boot Revision
Application Code Revision Displays the revision number of the application code running
Current Operational Mode Indicates the current operational mode of the encoder. The
Temperature
Fan Status
Slot ID
Overloaded Count
CPU Utilization (%)
System Up Time
Total System Up Time
System Date & Time
VBrick 9000 Encoder Admin Guide
Description
Displays current boot revision.
on the encoder.
following modes are supported. See Operational Modes for
more information.
• Run – Normal operation.
• Diagnostics – User selected mode for running certain
VBrick diagnostics. See Device Tests for information.
• Maintenance – Not selectable. Automatically launched
when the software on the VBrick encoder does not load.
• Limited Run – Not selectable. Normally occurs if a
hardware problem exists within the encoder but it can still
partially operate.
• Overloaded – Not selectable. This mode occurs when the
encoder is configured to handle more video than its
operational capacity. If this occurs, the encoder needs to be
reconfigured to reduce the number of streams and/or data
rates. Under this condition, the encoder temporarily
reduces video traffic in order to maintain VBAdmin
functionality.
Displays the encoder temperature in Celsius (for example 60º
Celsius = 140º Fahrenheit). A temperature exceeding 72º C will
cause an alarm, a trap, and a log message; if the temperature
drops below 72° C the alarm and trap will clear. When the
temperature exceeds the maximum threshold (81º), the
encoder will reboot and come up in Limited Run Mode; when
the temperature drops to an acceptable level, reboot the
encoder to return to normal Run Mode. The temperature (in
Celsius) determines the fan speed as follows:
• If temperature > 60º fan speed = Full 100%
• If temperature < 60º fan speed = Low 10%
On | Off | Alarm.
Blade Server only. Indicates slot number of blade in server
chassis. Blades are numbered 1–11 from left to right.
Provides a count of the number of times the box has entered
the Overloaded Mode.
Shows average CPU utilization percentage over the previous
10 seconds.
Total up time since last power cycle.
Aggregate up time since customer delivery.
Read-only. Set date and time on System Configuration >
General page.
Monitor
141