• Backup Speed Source
If the primary speed source fails, the display will use the backup if one is available.
• Manual Speed
If both of the speed input sources are unavailable, manual speed can be used in order for the control
channel to provide application. Manual speed setting for use during static machine testing or by the control
system in the absence of primary and backup speed signals.

Automatic Swath Control Settings

• Turn-On Look-Ahead
Determines how far ahead the system looks to turn the swath sections back on. This setting compensates
for any delay in the product control system when the sections are turned on.
• Turn-Off Look-Ahead
Determines how far ahead the system looks to turn the swath sections off. This setting compensates for
delay in the product control system when the boom sections are turned off.
• Outside Boundary Option
Determines the behavior of the sections when exiting the field boundary or prescription-mapped area.
• Coverage Option
Based on the coverage option selected, this setting determines the behavior of the swath section when
entering/exiting an already applied area or field boundary. Options available include Minimize Skip,
Minimize Overlap, and User Defined Percentage.

Auxiliary Input Settings

• Master Switch
Switch that performs global master control of all rate control channels.
• F1-F11
Settings determine the switch(es) that will operate the controlling channel specified from the configuration
setup. Single switches can be used to control multiple channels and swath sections.

Controller Settings

• Flow Meter Cal
Calibration value representing the number of pulses that equal one gallon of product flow through the
controlling system.
• Control Valve Configuration
Setting specifies the type of control valve being used for the rate control functions of the controlling system.
• Response Threshold\
Determines where the control channel switches between using Valve Response 1 and Valve Response 2
speed setting.
• Valve Response 1
Determines the speed of the servo valve when product control error exceeds the Response Threshold
setting. Valve Response 1 represents the fast speed of the servo valve.
• Valve Response 2
Determines the speed of the servo valve when product control error is less than the Response Threshold
setting. Valve Response 2 represents the slow speed of the servo valve.