Temperature Calibration

the same shaded area.
3. Press Temperature Button on Calibration Tab
On the display, go to the Calibration Tab and press the Temperature button. The Temperature Calibration
screen appears, as shown.
4. Enter Outside Air Temperature
Use the up and down arrow keys to enter the known outside air temperature. As you press the keys, the
Offset number changes to reflect the new temperature calibration. Press the checkmark box when
complete.

Moisture Calibration

On the display, go to the Calibration Tab. Use the drop-down menu to select the crop to calibrate. Next,
press the Moisture button. The Moisture Calibration screen appears, as shown.
3. Choose Field, Region, and Adjust Moisture
Choose the correct field and region the moisture sample was taken from. Use the up and down arrow keys
to adjust the moisture so that it matches the known moisture of the sample. When finished, press the
checkmark box.
Note: To use one constant moisture, select the Use Manual Moisture check box and use the arrow keys to
adjust to the desired percentage.

Grain Weight Calibration

Before the display can accurately measure harvested bushels, you must calibrate the display by entering
in actual load weights into the display for each grain type. You must obtain these actual load weights by
weighing the grain from a load on accurate scales. To obtain accurate results, you must obtain between
A Temperature Calibration only needs to be performed once
per season. Changing this calibration will affect previously
harvested data.
1. Place Combine in Shady Spot
Leave the combine parked in a shaded area or a shed for a few
hours. The temperature calibration should not be performed if the
sensor has been in direct sunlight or is sitting next to grain.
2. Take Air Temperature Reading
Take an accurate air temperature reading using a thermometer in
A moisture calibration only needs to be done once per crop per
season. Changing this calibration will affect previously-
harvested data.
1. Measure Moisture on Grain Samples
Harvest one load of grain. Randomly sample grain from several
locations in the grain tank to collect an average moisture for this
load, then measure the actual moisture using an accurate moisture
tester.
2. Press Moisture Button on Calibration Tab