3. Check the switch status found under Input Diagnostics. As the master switch is turned on and off, the
Input Diagnostics Screen should change from black to green (if they do not, then refer to the installation
instructions to verify switch connections).
4. Check high current connection into the Granular Control Module.
Problem: Master switch will not turn on when the foot pedal is on.
Solution: Make sure the Master Switch Input is set to "External 2" under the Auxiliary Input
Settings.
Problem: AutoSwath turns on the booms too fast or too slow.
Solution: Check GPS offsets in the vehicle setup to verify all of the measurements are
correct.
Problem: AutoSwath feature is not shown.
Solution: The display must have the AutoSwath feature password-unlocked before the
feature is available to the operator.
Problem: AutoSwath is checked on, but the spreader will not turn on.
Solution:
1. Make sure the ground speed is registering a value greater than zero on the display.
2. Make sure the applicator is inside of the field boundary.
Problem: Conveyor turns off in the middle of the pass
Solution: Check the display firmware and module firmware to see if they are running the
latest version.
Problem: Total Applied does not match Actual Weight Applied
Solution:
1. 1. Make sure the shaft speed ps/rev are set correctly in the controller settings.
2. 2. Make sure the controlling product is set to the correct units.
Problem: Rate not responding
1. 1. Make sure there is a ground speed registering on the display.
2. 2. Make sure the shaft speed pls/rev. are set correctly in the controller settings. (You must make sure
to account for sprocket ratios if chain driven).
Driven Teeth
Drive Teeth
3. 3. The CFR number may need to be adjusted.
T
ROUBLESHOOTING
G
)
RANULAR
Problem: Rate changes in the display, but not on the controlled console.
Solution:
1. Verify that the current firmware is running on the display and Application Rate module.
2. Check the settings specific to your controlled console (For more information, refer to the Quick
Reference Guide).
X Rate Sensor Pulses = True Pulses
S
C
ERIAL
ONTROL
A
PPLICATIONS