Dickey-john Flow Meter Calibrations on
• Raven flow meter tags represent pulses per 10 gallons. Divide the calibration number by 10 before
entering into the display.
• Tee Jet flow meter calibration numbers represent pulses per liter. To convert the number, multiply the
value found on the flow meter by 3.79 to find the pulses per gallon needed for the display.
• Mid-Tech flow meters sometimes have a cable with a module. The calibration number found on this cable
is in pulses/gal divided by 16. The display should bypass this module and plug directly into the flow
meter. If that is the case then multiply the calibration number by 16 before entering into the display.
6. Select Container
The Operating Configuration Wizard reappears. Select a container from the drop-down list, or press the
New button to create a new container.
-a. The Container Setup Wizard appears. Enter a container capacity and units, then press the blue right-
arrow button to continue.
-b. Enter a container name and location. Press the checkmark box.
7. Select Ground Speed Source
The Operating Configuration Wizard reappears. Select a primary and backup Ground Speed Source. In
most cases GPS is the primary speed source with Radar serving as backup. If you are using a backup radar
speed source it is recommended that you calibrate it before the season begins. When finished, press the
blue right-arrow button to continue.
Note: Ground Speed calibrations are completed under the Calibrate Distance button on the Application
Setup Configuration screen.
8. Edit Configuration Name
The Configuration name defaults to a name based on your previous configuration settings. To edit the
name, press the keyboard button and type a new name.
9. Finish Configuration
Press the checkmark box to complete the wizard and to save the configuration into the display.
138
-a.The Controller Setup Wizard appears. Select DirectCommand
from the drop-down list. Under the Direct Type list, select Liquid
Product Control. Press the blue right-arrow button to continue.
-b.Enter the Flow Meter Calibration Number by using the numeric
keypad to set the pulses per gallon. (This usually is tagged on the
flow meter). Press the blue right-arrow button to continue.
Notes for specific flow meters:
• For more information regarding Dickey-john Flow meters or
Dickey-john heat exchangers, see the Application section for
"Dickey John NH3 Conversions" on page 127.
-c.Enter a controller name. A default name of DirectLiquid appears.
If you would like to change this name, press the keyboard button,
enter a new name and press the checkmark box.