Controller Settings - PWM

Note: See PWM valve manufacturer information for recommended settings.
• PWM Gain
This setting determines how aggressively the control valve responds when making rate change
adjustments. The higher the value the more aggressive the system response is.
• Zero Flow Offset
This setting represents the maximum duty cycle that is sent to the control valve without producing any
hydraulic flow from the PWM valve. Using too high of a Zero Offset value can cause the product control
system to not properly shut off.
Note: See PWM valve manufacturer information for recommended settings.
C
S
ONTROLLER
• Controller Settings
Displays control valve settings for PWM and Servo Valve Controls.
For PWM Valve Control Settings, see
. For Servo Valve Control Settings, see
on page 139
Settings - Servo, Calibrated Reflow or Ramsey Valve" on page 140.
• Main Pressure
Pressing the Main Pressure button summons the Pressure Sensor
Calibration Wizard, as shown. Follow the steps in the Wizard to
complete the Pressure Calibration process.
• Agitation Pressure
Pressing the Agitation Pressure button summons the Pressure
Sensor Calibration Wizard, as shown. Follow the steps in the
Wizard to complete the Pressure Calibration process.
• PWM Frequency
The frequency that the PWM control valve is pulsed at. Typical
settings range from 100-125.
ETTINGS
"Controller Settings - PWM"