Configuration Settings - DirectCommand

Configuration Settings - DirectCommand
by the control system.
- Rx Default = Product will be applied at the default rate setting
• Minimum Flow
setting is used to maintain a consistent spray pattern. The display will not allow flow to drop below the
entered setting. Set to flow at the lowest operating pressure for the selected spray tips with all sections on.
When spraying with one or more boom sections off, the system automatically reduces the minimum flow
setting according to the reduced spray width. To adjust this setting, select the keyboard button and enter
the desired numeric value.
• Controller Time Delay
setting compensates for any latency in the control system when changing between different product flow
rates during variable rate application. The typical setting range for this is 0-8 seconds.
S
I
PEED
NPUT
The Speed Input Settings screen is where you can calibrate the ground speed input for accurate speed
and area calculations. If you are not using GPS for ground speed, then after you have created a
configuration you must calibrate the ground speed input. If you are using GPS, it is recommended to
calibrate distance in the event of GPS loss.

Calibrate Distance

1. Open Configuration Information screen
On the Configuration Tab, press the configuration name to highlight it, then press the Wrench
Button, and the Configuration Settings screen appears. Press Speed Input, and the Speed
Input screen appears as shown.
104
The Equipment Configuration screen is shown. This screen
displays the Implement and Controller information. To edit
equipment configuration settings, highlight a configuration and
press Edit.
• Configuration Name
The configuration name can be changed by pressing the on-screen
keyboard.
• Rate Outside of Field
selection determines product control channel behavior when the
field boundary is exited.
- Zero = Product application will turn off.
- Last Good = Product application will continue at the last value used