1. Verify that the rate display smoothing option is checkmarked in the setup of the configuration.
2. Check the controller settings of the active configuration. Verify that the valve setting for your particular
type of control valve agree with the settings given in the Quick Reference Guide.
3. Use manual valve control to see if the rate stays constant.
Problem: Erratic behavior from the flow meter and boom valves
Solution: Verify that the display firmware and module firmware are both current.
Problem: No boom pressure at the start of the field.
Solution: Use the Manual Valve Control to build boom pressure at the start of a field.
Problem: AutoSwath feature not shown.
Solution: The display must have the AutoSwath feature password unlocked before the
feature is available to the operator.
Problem: AutoSwath checked on, but booms will not turn on.
Solution:
1. Make sure the ground speed is registering a value greater than zero on the display and not in a
covered area.
2. Make sure there is a target rate greater than 0.
3. Make sure the applicator is inside of the field boundary.
Problem: Booms turn on in the middle of the pass.
Solution:
1. Check the display firmware and module firmware to see if they are the latest version released.
2. Make sure the ground speed does not go to 0.
3. Make sure the GPS is not losing the differential source.
Problem: Rate not responding (error flashing)
Solution:
1. Make sure the flow meter calibration number matches the tag on the flow meter.
Note: For Raven flow meters, divide the calibration number by 10.
2. Make sure the pump is not maxed out for the flow being applied.
3. Use manual valve control to see if the control valve will open or close.
4. Check the tip manufacturer's charts to make sure they are in the operating range of the application.
5. Check for any product buildup in the flow meter.
6. Check product filter for debris.
Problem: Booms turn on when outside of the boundary.
Solution:
1. 1. Make sure the Rate Outside of Field is set to zero under the active configuration settings.
2. Make sure the Outside Boundary Option is set to Turn Selection Off under the Automatic Swath Control
option.