ROUBLESHOOTING
Problem: Individual implement Sections shown in the Implement Icon on the Map Zoom Detail
Screen do not turn green.
Solution:
1. Make sure ground speed has registered a value greater than zero on the display.
2. Verify a target rate greater than zero is entered into the display.
160
F
S
LOW
ENSOR
Module Auxiliary Connection
12-Pin Socket
11
9
8
The injection pump has a vacuum switch that is used to warn operators of
any restriction at the inlet of the pump. The sensor is a normally closed
switch that opens if a restriction is encountered in the injection system. A
warning will be displayed for the operator if the vacuum switch opens due to
restriction. See table below for pin locations. The operator can test the
system by unplugging the sensor, which will trigger the warning. If the
operator jumps pins A and C, the warning will end.