Liquid Pwm Control Valve Settings Description; Spinner Spreader Servo Settings Description - Ag Leader EDGE User Manual

Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

L
PWM C
IQUID
• PWM Frequency
Default Value: 100
The frequency that the PWM control valve is pulsed at. Typical settings range from 100 - 125. See PWM
valve manufacturer information for recommended settings.
• Gain
Default Value: 800
This setting determines how aggressively the control valve responds when making rate change
adjustments. The higher the value the more aggressive the system response is.
• Zero Offset
Default Value: 30
This setting represents the maximum duty cycle that is sent to the control valve without producing any
hydraulic flow from the PWM valve. Using too high of a Zero Offset value can cause the product control
system to not properly shut off. See PWM valve manufacturer information for recommended settings.
• Allowable Error
Default Value: 2%
2% - 3% is the normal dead band setting range.
- Too low of a setting value can cause the product control system to continually hunt for the target
application rate.
- Too high of a setting will cause excessive product application error.
S
S
PINNER
PREADER
• Valve Response 1
Default Value: 40%
Determines the speed of the servo valve when product control error exceeds the Response Threshold
setting
Decreasing the value will cause the servo valve to run slower.
• Valve Response 2
Default Value: 8%
Determines the speed of the servo valve when product control error is less than the Response Threshold
setting.
Decreasing the value will cause the servo valve to run slower.
• Allowable Error
Default Value: 2%
Determines the percent of error that is allowed prior to the product control system making any conveyor
RPM corrections.
2% - 3% is the normal dead band setting range.
- Too low of a setting value can cause the product control system to continually hunt for the target
application rate.
- Too high of a setting will cause excessive product application error.
• Response Threshold
Default Value: 15%
V
ONTROL
ALVE
S
S
ERVO
S
D
ETTINGS
ESCRIPTION
D
ETTINGS
ESCRIPTION
125

Advertisement

Table of Contents
loading

Table of Contents