Pilz PMCtendo DD5 Operating Manual page 93

Servo amplifier
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

Wiring
Connector X8
X8
Connector pin assignment
Output circuit
Servo Drive
Connection
Use the following fuses for F
Fuses – Use in CE regions
Rated voltage
power supply
110/115 V
230 V
400 V
Operating Manual PMCtendo DD5
1002236-EN-04
Pin
Designation
3
+RBext
1 -DC
2 n.c.
5
-RB
3 +RBext
4 +RBint
5 -RB
X8
1
-DC
3
+RBext
4
+RBint
5
-RB
and F
B1
INFORMATION
The specified fuses do not protect the external brake resistor from thermal
overload. Monitoring is carried out by the servo amplifier via software. It is
assumed that the parameters on the servo amplifier are set correctly. The
fuses should provide protection from consequential damage in the event of
a short circuit and earth fault.
Voltage class of DC
fuse
min. 250 VDC
min. 250 VDC
min. 440 VDC
Description
Connection of external brake res-
istor +
Connection of external brake res-
istor -
F B1
R Be
F B2
, depending on the device type.
B2
Device type
PMCtendo DD5
.03/230
.06/230
.10/230
6 A
6 A
Motor with brake
Internal brake resistor:
Link Pin 4 (+RBint) and
Pin 5 (-RB)
External brake resistor:
Remove the link between
Pin 4 (+RBint) and Pin 5 (-
RB)
Device type
PMCtendo DD5
.01/480
.03/480
.06/480
6 A
6 A
93

Advertisement

Table of Contents
loading

Table of Contents