Chokes; Power Element; Mains Voltage - Pilz PMCtendo DD5 Operating Manual

Servo amplifier
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

Wiring
6.5.4

Chokes

If motor cables are > 25 m, a choke must be used on the servo amplifier's output.
The choke is used to
}
Reduce the level of interference on the motor cable
}
Deal with EMC problems retrospectively
}
Protect the semiconductor on the inverted rectifier in the case of an earth fault or short
circuit
}
Protect the motor from high voltage rise rates
Additional earthing measures are unnecessary because, unlike filters, chokes do not have
to divert disturbances to earth.
6.6

Power element

6.6.1

Mains voltage

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
Please note the following important points under "Mains voltage", in the chapter entitled
"Function description":
}
The mains voltage requirements (network configurations)
}
The use of isolating transformers
Connector X0
Connector pin assignment
Operating Manual PMCtendo DD5
1002236-EN-04
WARNING!
In a residential environment this product may cause high-frequency noise,
so that suppression measures may be required.
CAUTION!
Risk of overvoltage
Overvoltage can destroy the device and lead to minor injuries.
Select the correct mains voltage and the correct device type.
Pin
1
X0
1 PE
2
2 L3
3
3 L2
4
4 L1
Designation
PE
L3
L2
L1
Description
Earth conductor
Mains voltage phase L3
Mains voltage phase L2
Mains voltage phase L1
89