Encoder Systems; Hiperface Dsl, One-Cable Connection - Pilz PMCtendo DD5 Operating Manual

Servo amplifier
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

Wiring
Input circuit
Servo Drive
Connection
6.7.5

Encoder systems

6.7.5.1

HIPERFACE DSL, one-cable connection

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
Operating Manual PMCtendo DD5
1002236-EN-04
X3
3
ANALOG-IN1+
4
ANALOG-IN1-
5
ANALOG-IN2+
6
ANALOG-IN2-
7
AGND
Shield
NOTICE
The connection cable must not exceed the maximum length of 25 m.
The connection cable must not be interrupted or separated.
Analogue input
- Signal range –10 ... +10 V
- Referenced to earth: Al-
-O1
ways connect AGND (X3/7)
+/- 10 V
+O1
to CNC-GND on the control
system
-O2
+/- 10 V
- Twisted pair, shielded
+O2
- Shield connection on the
CNC-GND
front plate
GND
103