Pilz PMCtendo DD5 Operating Manual page 155

Servo amplifier
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

Commissioning
Fig.: Minimum configuration for commissioning
}
S1: Switches on 24 VDC supply voltage
}
S2: Enables the servo amplifier (hardware enable)
}
S3: Switches on mains contactor, provides mains voltage to servo amplifier
}
K1: Mains contactor (optional, power is removed)
}
A1: Mains contactor 24 V +
}
A2: Mains contactor 24 V -
Wire components
}
24 VDC supply voltage ("+" to X4/1 via S1 switch and "-" to X4/3)
}
Enable hardware: Connect 24 VDC to terminal X3/12 via S2 switch
}
Mains contactor K1
}
"STO-ENABLE deactivated" mode: Link terminals X4/5 and X4/1
}
Voltage for relay contact for operational readiness BTB/RTO: Link terminals X4/5 and
X3/2
Operating Manual PMCtendo DD5
1002236-EN-04
Connect A1 terminal to X3/1 via S3 switch
Connect A2 terminal to DGND on the supply voltage
3
ANALOG-IN1+
+/- 10 V
4
ANALOG-IN1-
155