Pilz PMCtendo DD5 Operating Manual page 145

Servo amplifier
Hide thumbs Also See for PMCtendo DD5:
Table of Contents

Advertisement

Wiring
Output of SSI signals
Connector X5
Connector pin assignment
Output circuit
Servo Drive
Connection
6.7.6
Communication interfaces
6.7.6.1
RS232 interface
We recommend shielded cable for the RS 232 interface.
If you use unshielded cables, the interface may malfunction.
}
Earth the cable shielding on both sides (e.g. on a bus bar).
}
Transient currents can be anticipated on longer cables. If this is the case you should
use equipotential bonding cables.
}
With the supply voltages switched off, connect the interface (X6) on the servo amplifier
to a serial interface on the PC via a null modem cable.
Operating Manual PMCtendo DD5
1002236-EN-04
Pin
1
1
6
2
9
3
5
4
5
6
7
8
9
n. c.: Not connected
X5
6
DATA
7
DATA\
4
CLOCK
R T
5
CLOCK\
1
GND
Designation
GND
n. c.
n. c.
CLOCK
CLOCK\
DATA
DATA\
n. c.
n. c.
DATA
R T
DATA\
CLOCK
CLOCK\
GND
Description
Ground
--
--
Pulse signal
Pulse signal inverted
Channel B
Channel B inverted
--
--
Output of SSI signals
Shield connection in the
PLC
connector
Always connect GND to the
earth on the control system
Select RT in accordance
with the cable impedance,
typically 150 Ω
145