Overview
Integrated safety
}
Device safety
}
Protection of personnel and plant
Expansion cards
}
1 slot for expansion cards:
Fieldbus junction box
}
CAN Adapter: Splits the combined RS232/CANopen interface on the PMCtendo DD5
into one RS232 interface and two CANopen interfaces wired in parallel
Operating Manual PMCtendo DD5
1002236-EN-04
Safe electrical isolation between mains voltage/motor connection and control ele-
ment, in accordance with EN 61800-5-1
Soft start, overvoltage detection, short circuit protection, phase failure monitoring
Temperature monitoring of servo amplifier and motor (when using Pilz motors with
ready-made cables)
Safety function STO – Safe Torque Off
Single-channel without feedback: Up to PL d (Cat. 2) of EN ISO 13849-1 and
SIL CL 2 of EN/IEC 62061
I/O
PROFIBUS
PROFINET
EtherCAT (cannot be retrofitted)
Fan controller, available only on request