Wiring
}
All shielded cables are to be attached at both ends to the shield terminals provided or
should be connected to the connector housing.
}
Use cables with braided shield, with a minimum cover area of 80 %.
}
Any interruptions to the shielding e.g. at terminals, contactors, chokes, should be
bridged at low impedance over a wide area.
}
All connectors or sockets should be fastened with screws to ensure ample, conductive
contact between the braided shield and the front plate.
6.5.2.1

Shield connection on the front plate

6.5.2.2

Motor connection

The cable shield for the motor cable is connected to the servo amplifier housing via the
shielding plate.
Use the ready-made motor cable from Pilz (accessory). However, If you wish to wire your
own motor connector, follow the instructions below:
Operating Manual PMCtendo DD5
1002236-EN-04
(1)
(2)
(3)
(2)
(4)
Remove the outer cable sheath and the
braided shield to the required wire length.
Secure the wires with a cable tie.
Remove the outer cable sheath to a length
of approx. 30 mm. Be careful not to damage
the braided shield.
Strip all the wires and fit end ferrules.
Use the cable ties to attach the cable to the
shielding plate on the side (1) or bottom (3)
of the servo amplifier. Press the cable's
braided shield firmly against the shielding
plate on the servo amplifier using a cable tie
(2).
Alternatively you can use the shielded con-
nection terminals (4) (available as an ac-
cessory). These hook into the bottom
shielding plate and guarantee optimum con-
tact between the shield and the shielding
plate.