Method For Setting Positioning Data; Setting By Designating Numerical Values - Mitsubishi Electric A173UHCPU Programming Manual

Motion controller
Hide thumbs Also See for A173UHCPU:
Table of Contents

Advertisement

6. SERVO PROGRAMS FOR POSITIONING CONTROL
6.4

Method for Setting Positioning Data

6.4.1

Setting by designating numerical values

This section explains how to set the positioning data used in a servo program.
There are two ways to set positioning data, as follows:
(1) Designating numerical values ....................... see Section 6.4.1
(2) Indirect designation using word devices ....... see Section 6.4.2
It is possible to combine data setting by designating numerical values and indirect
designation using word devices in the same servo program.
The method of setting by designating numerical values is a method whereby each
positioning data item is set as a numerical value and becomes fixed data.
Data can only be set and corrected at a peripheral device.
Positioning
data
Fig. 6.3 Example of Setting Positioning Data by Numerical Value Setting
<K 11>
ABS-3
Axis
1,
3000000.0
Axis
2,
5500000.0
Axis
3,
-2500000.0
Combined speed
40000.00
Dwell
2500
M-code
12
P.B.
6 − 13
Numerical value setting for
positioning data
Become fixed data for one
serve program
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A273uhcpu

Table of Contents