7. POSITIONING CONTROL
JOG Operation
No.
Forward
Reverse
JOG
1
M3202
2
M3222
3
M3242
4
M3262
5
M3282
6
M3302
7
M3322
8
M3342
9
M3362
10
M3382
11
M3402
12
M3422
13
M3442
14
M3462
15
M3482
16
M3502
17
M3522
18
M3542
19
M3562
20
M3582
21
M3602
22
M3622
23
M3642
24
M3662
25
M3682
26
M3702
27
M3722
28
M3742
29
M3762
30
M3782
31
M3802
32
M3822
(2) The JOG operation signal, JOG operation setting register, and setting range for
each axis are shown in the table below.
JOG Operation Setting Register
Most
JOG
Significant
M3203
D641
M3223
D643
M3243
D645
M3263
D647
M3283
D649
M3303
D651
M3323
D653
M3343
D655
M3363
D657
M3383
D659
M3403
D661
M3423
D663
M3443
D665
M3463
D667
M3483
D669
M3503
D671
M3523
D673
M3543
D675
M3563
D677
M3583
D679
M3603
D681
M3623
D683
M3643
D685
M3663
D687
M3683
D689
M3703
D691
M3723
D693
M3743
D695
M3763
D697
M3783
D699
M3803
D701
M3823
D703
POINT
To set the JOG operation speed using a sequence program, store a value in
the JOG operation speed setting register which is 100 times the real speed in
units of millimeters or 1000 times the speed in units of inches or degrees.
Example
To set a JOG operation speed of 6000.00 mm/min., store the value
600000 in the JOG operation speed setting register.
mm
Least
Setting
Units
Significant
Range
D640
D642
D644
D646
D648
D650
D652
D654
D656
D658
D660
D662
D664
D666
D668
-2
10
D670
1 to
mm/
600000000
D672
min
D674
D676
D678
D680
D682
D684
D686
D688
D690
D692
D694
D696
D698
D700
D702
7 − 128
inch
degree
Setting
Setting
Units
Units
Range
Range
-3
10
10
1 to
1 to
inch/
degree
600000000
2147483647
min
/min
PULSE
Setting
Units
Range
-3
1 to
PLS/s
10000000

Hide quick links:

Advertisement

Table of Contents
loading