7. POSITIONING CONTROL
7.16.1

Setting Pass points using Repeated Instructions

Servo
Positioning
Instruction
Method
FOR-TIMES
FOR-ON
FOR-OFF
NEXT
[Control Details]
This section describes the method of designating the pass points used for repeated
execution between pass points.
Common
Number of
Controllable
Axes
Setting the start of the repeated range
The start of the repeated range is designated using the following instructions:
(1) FOR-TIMES (number of loops setting)
(a) The designated repeated range is executed the set number of times.
(b) The setting range is (1 to 32767).
If an out-of-range setting between −32768 and 0 is designated, control is
executed with a setting of "1".
(c) The following devices are available to set the number of repetitions:
1) Data register (D)
2) Link register (W)
3) Decimal constant (K)
4) Hexadecimal constant (H)
(2) FOR-ON (loop-out trigger condition setting)
(a) The set repeated range is executed while the designated bit device is ON.
(b) The following devices are available to set the loop-out trigger condition:
1) Input (X)
2) Output (Y)
3) Internal relay (M)/Special relay (SP.M)
4) Latch relay (L)
5) Link relay (B)
6) Annunciator (F)
Items Set by Peripherals
Arc
Indirect designation
7 − 95
Parameter Block
"
Others
" : Must be set
∆ : Set if required