Table 2.12 Servo Amplifier Error List (2000 to 2799) (Continued)
Error
Amplifier
Code
Type
Name
2301
Parameter
M
to
alarm
2336
Error Cause
Description
• The servo parameter value is outside
the setting range. (Any unauthorized
parameter is ignored and the value
before setting is retained.)
2301
Amplifier setting
2302
Regenerative resistance
2303
Motor type
2304
Motor capacity
2305
Motor rpm
Number of feedback
2306
pulses
Rotating direction
2307
setting
2308
Automatic tuning setting
2309
Servo responsibility
2310
Torque limit (forward)
2311
Torque limit (reverse)
2312
Load inertia ratio
2313
Position control gain 1
2314
Speed control gain 1
2315
Position control gain 2
2316
Speed control gain 2
Speed integral
2317
compensation
2318
Notch filter
2319
Feed forward coefficient
2320
In-position range
Electromagnetic brake
2321
sequence output
Monitor output mode
2322
selection
2323
Optional function 1
2324
Optional function 2
2325
Optional function 3
2326
Optional function 4
2327
Monitor output 1 offset
2328
Monitor output 2 offset
2329
Pre-alarm
data
selection
2330
Zero speed
2331
Excessive error alarm
level
3232
Optional function 5
3233
Optional function 6
2334
PI-PID switching
position droop
2335
Torque limit
compensation factor
2336
Speed integral
compensation (actual
speed differential
compensation)
When Error Checked
Error Processing
Operation
At any time during operation
continues
APP − 29
Corrective Action
• Check the setting ranges of the servo
parameters.