Pos : 682 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Mel dungen Eins chalts perre (T abellenüberschrift) @ 3\mod_1361803467385_388.doc x @ 59922 @ 5 @ 1
Switch-on block messages
Display in the
SimpleBox /
Reason:
ControlBox
Text in the ParameterBox
Group
Details in
P700 [-03]
Pos : 683 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I000_01 [SK 180E ... SK 5xxE] @ 2\mod_1347457775195_388.doc x @ 47347 @ @ 1
I000
0.1
Disable voltage from IO
0.2
IO fast stop
0.3
Block voltage from bus
0.4
Bus fast stop
0.5
Enable on start
0.6 – 0.7
Reserved
Pos : 684 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I000_02-Erg änz ung 08 und 09 [SK 180E ... SK 5xxE] @ 10\mod_1455725649528_388.doc x @ 306332 @ @ 1
0.8
Right direction blocked
0.9
Left direction blocked
Pos : 685 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I006 [SK 180E ... SK 5xxE] @ 2\mod_1347457929759_388.doc x @ 47372 @ @ 1
1)
6.0
Charging error
I006
Pos : 686 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I011 [SK 180E ... SK 5xxE] @ 2\mod_1347457936856_388.doc x @ 47397 @ @ 1
I011
11.0
Analog Stop
Pos : 687 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I014 "res er viert" [SK 200E ... SK 5xxE] @ 2\mod_1347457944329_388.doc x @ 47422 @ @ 1
1)
I014
14.4
Reserved
Pos : 688 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation I018 "res er viert" [SK 2xxE/ SK 5xxE/ SK 2xxE-FDS] @ 2\mod_1347457946544_388.doc x @ 47447 @ @ 1
1)
I018
18.0
Reserved
Pos : 689 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/Infor mation - Kennzeic hnung "Nic ht ber eit" @ 20\mod_1513067472948_388.doc x @ 2375129 @ @ 1
1)
Indication of operating mode (message) on the ParameterBox or virtual operating unit of the NORD CON-Software: "Not ready"
Pos : 690 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
6 Operating status messages
Cause
•
Remedy
If the function "disable voltage"is parameterised, input (P420
/ P480) is at Low
Set "input High"
•
Check signal cable (broken cable)
•
If the function "fast stop"is parameterised, input (P420 /
P480) is at Low
•
Set "input High"
•
Check signal cable (broken cable)
For bus operation (P509):
•
"Low"
•
For bus operation (P509):
"Low"
Enable signal (control word, Dig I/O or Bus I/O) was already
applied during the initialisation phase (after mains "ON", or
control voltage "ON"). Or electrical phase is missing.
Only issue enable signal after completion of
•
initialisation (i.e. when the FI is ready)
Activation of "Automatic Start" (P428)
•
Information message for PLC see supplementary
instructions
Switch-on block with inverter shut-off activated by:
P540 or by "Enable right block" (P420 = 31, 73) or "Enable
left block" (P420 = 32, 74),
The frequency inverter switches to "Ready for switching on"
status
Charging relay not energised, because:
Mains / link voltage too low
•
Mains failure
•
Evacuation run activated ((P420) / (P480))
•
If an analog input of the frequency inverter or a connected
IO extension is configured to detect cable breaks (2-10V
signal or 4-20mA signal), the frequency inverter switches to
the status "ready for switch-on" if the analog signal
undershoots the value 1 V or 2 mA
This also occurs if the relevant analog input is
parameterised to function "0" ("no function").
•
Check connections
Error message for POSICON see supplementary
instructions
Information message for "Safe Stop" function see
supplementary instructions
control word Bit 1 is
control word Bit 2 is