17 = Reference value Ain2,
SK 2x0E:
Setpoint AIN2 of the FI is compared with the value in (P435[-01 or -02]).
SK 2x5E: Setpoint AIN2 of 1st IO extension is compared with value in
(P435[-01])
18 = FI ready: The FI is ready for operation. After being enabled it delivers an
output signal.
19 = ... 29 Reserved
30 = Digital-In 1 status
31 = Digital-In 2 status
32 = Digital-In 3 status
33 = Digital-In 4 status
38 = Value from bus setpoint
39 = STO inactive
40 = Output via PLC: The output is set by the integrated PLC
Pos : 452 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P434 – Digitalausg ang_Infor mati on "l ow-akti ve Ei nstellungen/F unktionen" [alle FU ] @ 19\mod_1505978722699_388.doc x @ 2365689 @ @ 1
If the frequency inverter is not in operation, i.e. no mains or control voltage is connected, all
output functions are without function ("low"). This means that for the use of settings or
functions which are "low" active (e.g setting 7  Fault) the following must be taken into
account:
Evaluation of the output signal of the device, e.g. by a PLC must be compared with the basic
readiness for operation of the frequency inverter.
Pos : 453 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P435 – Nor mi erung Digitalausgänge [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931807892_388.doc x @ 42792 @ @ 1
P435
Dig. out scaling
[-01]
[-02]
(Scaling of digital output)
[-01] =
-400 ... 400 %
[-02] =
{ 100 }
Adjustment of the limiting values of the output function. For a negative value, the output function
will be output negative.
Reference to the following values:
Pos : 454 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
Information
Digital output 1, Digital output 1 of the frequency inverter
Digital output 2, Digital output 2 of the frequency inverter SK 2x0E
Current limit (3) = x [%] ⋅ P203 >Rated motor current<
Torque current limit (4) = x [%] ⋅ P203 ⋅ P206 (calculated rated motor torque)
Frequency limit (5) = x [%] ⋅ P201 >Rated motor frequency<
POSICON functions see BU 0210)
"low" active settings / functions
5 Parameter
High
High
High
High
High
High
High
High
High