Nord Drivesystems NORDAC FLEX SK 200E Series User Manual page 178

Frequency inverters
Hide thumbs Also See for NORDAC FLEX SK 200E Series:
Table of Contents

Advertisement

NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Value
Function
2
66
Release brake manually
"Release brake manually"
67
Man/auto set dig. out.
"Set
digital
manually/automatically"
68
Digit. out. man. Set
"Set digital output manually"
69
Speed meas. with ini.
"Speed measurement with initiator"
70
Evacuation runs
"Activate evacuation run"
3
71
Motorpot.F+ and Save
"Motor potentiometer function
frequency + with automatic saving"
3
72
Motorpot.F- and Save
"Motor potentiometer function
Frequency - with automatic saving"
2
73
Clockw. disable + fast
"Disable clockwise rotation + Fast
Stop"
2
74
Anticlockw. disable + fast
"Disable anticlockwise rotation +
Fast Stop"
75
D. out. 2 man/ auto set
"Set
digital
manually/automatically"
76
D. out. 2 man. set
"Set digital output 2 manually"
77
...79 reserved for Posicon
80
PLC stop
1
If no digital output has been parametrised to "Right enable" or "Left enable" and with devices from SK 22xE, all AS-i related
BUS-In bits (P480) are deactivated and DIP switches S1 "3-5" are in the factory setting, the actuation of a fixed frequency or
the jog frequency leads to the enabling of the frequency inverter. The rotation field direction depends on the sign of the
setpoint.
2
Also effective for BUS control (e.g. RS232, RS485, CANopen, AS-Interface, ...)
3
With SK 2x5 devices the frequency inverter control unit must be supplied with power for a further 5 minutes after the last
change to the motor potentiometer in order to permanently save the data.
4
Function cannot be selected via BUS IO In Bits
5
The operating parameter set is selected via appropriately
parametrised digital inputs or BUS actuation. Switching can
take place during operation (online). Coding takes place
binary in accordance with the adjacent sample.
In the event of enabling via the keyboard (SimpleBox,
ControlBox,
PotentiometerBox
operating parameter set will match the settings in P100.
Pos : 446 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
178
Description
The brake is only released of the digital input is set.
Set digital output 1 manually, or via the function set in (P434)
output
Set digital output 1 manually
Simple speed measurement (impulse measurement) with initiator
This also provides the possibility of operation with a very low link
circuit voltage (e.g. using batteries). With this function the
charging relay is activated and existing monitoring functions are
deactivated.
NOTICE! There is no overload monitoring! (e.g. lifting gear)
This "motor potentiometer function" is used to set a setpoint
(amount) via the dig. inputs that is saved at the same time. With
control enabling R/L this is then started up in the correspondingly
enabled direction. On change of direction the frequency is
retained.
Simultaneous activation of the +/- function causes the frequency
setpoint value to be set to zero.
The frequency setpoint can also be set in the operating value
display (P001=30, 'Actual. setpoint MP-S') or displayed or set in
P718.
Any minimum frequency set (P104) is still effective. Other
setpoint values, e.g. analogue or fixed frequencies can be added
or subtracted.
The adjustment of the frequency setpoint value is performed with
the ramps from P102/103.
As for setting 31, however coupled to the function "Fast Stop".
As for setting 32, however coupled to the function "Fast Stop".
As for function 67, however for digital output 2 (only SK 2x0E)
output
2
As for function 68, however for digital output 2 (only SK 2x0E)
BU0210
The program execution of the integrated PLC is stopped for as
long as the signal is present.
or
ParameterBox),
Setting
0 =
Parameter set 1
1 =
Parameter set 2
the
2 =
Parameter set 3
3 =
Parameter set 4
Signal
High
High
High
Impulse
High
High
High
Low
Low
High
High
High
Digital input
Digital input
function [8]
function [17]
LOW
LOW
HIGH
LOW
LOW
HIGH
HIGH
HIGH
BU 0200 en-3118