NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 463 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P480 – Funktion Bus I/O In Bits [SK 1x0E, SK 2xxE] @ 2\mod_1346931810637_388.doc x @ 42888 @ @ 1
P480
[-01]
Function BusIO In Bits
...
(Bus I/O In Bits function)
[-12]
0 ... 80
The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions (P420).
{ [-01] = 01 }
With devices with an integrated AS interface, the I/O bits can be used by the interface itself
(bit 0 ... 3) or in combination with I/O extensions (SK xU4-IOE) (bits 4 ... 7 and bits 0 ... 3). With
{ [-02] = 02 }
AS-i devices, the priority is AS-i. In this case BUS IO BITs 1 ... 4 cannot be used by the 2nd. IO
{ [-03] = 05 }
extension.
{ [-04] = 12 }
[-01] = Bus / AS-i Dig In1
{ [-05...-12] = 00 }
[-02] = Bus / AS-i Dig In2
[-03] = Bus / AS-i Dig In3
[-04] = Bus / AS-i Dig In4
[-05] = Bus / IOE Dig In1
[-06] = Bus / IOE Dig In2
[-07] = Bus / IOE Dig In3
[-08] = Bus / IOE Dig In4
[-09] = Flag 1
[-10] = Flag 2
[-11] = Bit 8 BUS control word
[-12] = Bit 9 BUS control word
The possible functions for the bus In bits can be found in the table of functions for the digital
inputs in parameter (P420). Functions {14} "Remote control" and {29} "Enable SetpointBox" are
not possible.
1) The flag function is only possible with control via control terminals.
Pos : 464 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P481 – Funktion Bus I/O Out Bi ts [SK 1x0E, SK 2xxE] @ 2\mod_1346931811511_388.doc x @ 42912 @ @ 1
P481
[-01]
Function BusIO Out Bits
...
(Function of Bus I/O Out Bits)
[-10]
0 ... 40
The bus I/O Out bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434).
{ [-01] = 18 }
With devices with in integrated AS interface, the I/O bits can be used by the interface itself
{ [-02] = 08 }
(bit 0 ... 3) or in combination with I/O extensions (SK xU4-IOE) (bits 4 ... 5 and flags 1 ... 2).
{ [-03] = 30 }
[-01] = Bus / AS-i Dig Out1
{ [-04] = 31 }
[-02] = Bus / AS-i Dig Out2
{ [-05...-10] = 00 }
[-03] = Bus / AS-i Dig Out3
[-04] = Bus / AS-i Dig Out4
[-05] = Bus / IOE Dig Out1
[-06] = Bus / IOE Dig Out2
[-07] = Bus / 2nd IOE Dig Out1
[-08] = Bus / 2nd IOE Dig Out2
[-09] = Bit 10 BUS status word
[-10] = Bit 13 BUS status word
The possible functions for the Bus Out Bits can be found in the table of functions for the digital
outputs (P434).
1) The flag function is only possible with control via control terminals.
Pos : 465 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
184
(Bus IO In Bit 0 + AS-i 1 or DI 1 of the
(Bus IO In Bit 1 + AS-i 2 or DI 2 of the
(Bus IO In Bit 2 + AS-i 3 or DI 3 of the
(Bus IO In Bit 3 + AS-i 4 or. DI 4 of the
(Bus IO In Bit 4 + DI 1 of the
(Bus IO In Bit 5 + DI 2 of the
(Bus IO In Bit 6 + DI 3 of the
(Bus IO In Bit 7 + DI 4 of the
1)
1)
(Bus IO Out Bit 0 + AS-i 1)
(Bus IO Out Bit 1 + AS-i 2)
(Bus IO Out Bit 2 + AS-i 3)
(Bus IO Out Bit 3 + AS-i 4)
(Bus IO Out Bit 4 + DO 1 of the first SK xU4
(Bus IO Out Bit 5 + DO 2 of the first SK xU4
(Flag1
(Flag2
second
second
second
second
first
-
SK xU4
IOE (DigIn 05))
first
-
SK xU4
IOE (DigIn 06))
first
-
SK xU4
IOE (DigIn 07))
first
-
SK xU4
IOE (DigIN 08))
1)
+ DO 1 of the second SK xU4
1)
+ DO 2 of the second SK xU4
-
SK xU4
IOE (DigIn 09))
-
SK xU4
IOE (DigIn 10))
-
SK xU4
IOE (DigIn 11))
-
SK xU4
IOE (DigIn 12))
-
IOE (DigOut 02))
-
IOE (DigOut 03))
-
IOE (DigOut 04))
-
IOE (DigOut 05))
BU 0200 en-3118