Nord Drivesystems NORDAC FLEX SK 200E Series User Manual page 171

Frequency inverters
Hide thumbs Also See for NORDAC FLEX SK 200E Series:
Table of Contents

Advertisement

Pos : 428 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P403 – Abgleic h 100% [SK 2xxE] @ 2\mod_1346931799171_388.doc x @ 42479 @ @ 1
P403
[-01]
Adjustment: 100%
...
(Analogue input adjustment: 100%)
[-06]
-50.00 ... 50.00 V
[-01]
{ all 0.00 }
[-02]
[-03]
[-04]
[-05]
[-06]
This parameter sets the voltage which should correspond with the maximum value of the selected
function for the analogue input 1 or 2. In the factory setting (setpoint) this value is corresponds
with the setpoint set via P105 >Maximum frequency<.
Note
SK 2x0E
For the adjustment of the integrated analogue inputs of the SK2x0E to the type of analogue
signals, the following values must be set:
0 - 10V
2 - 10V
0 - 20mA
4 - 20mA
DIP switches: (please see chapter 4.3.2.3 "DIP switches, analogue input (only SK 2x0E)")
SK xU4-IOE
Standardisation to typical signals, such as 0(2)-10V or 0(4)-20mA is carried out via the DIP switch
on the I/O-extension module. In this case, additional adjustment of parameters (P402) and (P403)
must not be carried out.
Pos : 429 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P404 – Filter Anal ogei ngang [SK 1x0E, SK 2xxE, SK 54xE, SK 2xxE-FD S] @ 0\mod_1327681301144_388.doc x @ 9326 @ @ 1
P404
Analogue input filter
[-01]
[-02]
(analogue input filter)
10 ... 400 ms
Adjustable digital low-pass filter for the analogue signal. Interference peaks are hidden, the
reaction time is extended.
{ all 100 }
[-01] = Analogue input 1: analogue input 1 integrated in the device
[-02] = Analogue input 2: analogue input 2 integrated in the device
The filter time for the analogue inputs of the optional external IO extension modules is set in the
parameter set for the relevant module (P161).
Pos : 430 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
External Analogue input 1, AIN1 of the first I/O extension (SK xU4-IOE)
External Analogue input 2, AIN2 of the first I/O extension (SK xU4-IOE)
External A.in. 1 2nd IOE, "External analogue input 1 2nd IOE", AIN1 of the second I/O
extension (SK xU4-IOE) (= Analogue input 3)
External A.in. 2 2nd IOE, "External analogue input 2 2nd IOE", AIN2 of the second I/O
extension (SK xU4-IOE) (= Analogue input 4)
Analogue input 1, Analogue input1 (only SK 200E, SK 210E)
Analogue input 2, Analogue input 2 (only SK 2x0E)
→ 10.00 V
→ 10.00 V
→ 5.00 V (enable internal resistance via DIP switch!)
→ 5.00 V (enable internal resistance via DIP switch!)
5 Parameter
S
S
SK 2x0E
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents