Pos : 607 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P741 – Pr ozessdaten Bus Out [SK 1x0E, SK 2xxE, SK 500...535E, SK 2xxE-FDS] @ 0\mod_1328177890266_388.doc x @ 13359 @ @ 1
P741
[-01]
PZD bus Out
...
(Process data Bus Out)
[-19]
0000 ... FFFF (hex)
This
information about the actual
status word and the actual
values that are transferred
via the bus systems.
Standardisation:
( section 8.9
"Standardisation of setpoint
/ target values")
Pos : 608 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P742 – Datenbankversion @ 0\mod_1328178021821_388.doc x @ 13405 @ @ 1
Data base version
P742
(Database version)
0 ... 9999
Displays the internal database version of the FI.
Pos : 609 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P743 – U mrichtertyp @ 0\mod_1328178080214_388.doc x @ 13428 @ @ 1
Inverter type
P743
(Inverter type)
0.00 ... 250.00
Displays the inverter power in kW, e.g. "1.50" ⇒ FI with 1.5 kW nominal power.
Pos : 610 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
parameter
provides
[-01] = Status word
[-02] = Actual value 1 (P543)
[-03] = Actual value 2 (...)
[-04] = Actual value 3 (...)
[-05] = res.status OutBit P481
[-06] = Parameter data Out 1
[-07] = Parameter data Out 2
[-08] = Parameter data Out 3
[-09] = Parameter data Out 4
[-10] = Parameter data Out 5
[-11] = Actual value 1 master funct.
[-12] = Actual value 2 master funct.
[-13] = Actual value 3 master funct.
[-14] = Status word PLC
[-15] = Actual value 1 PLC
...
[-19] = Actual value 5 PLC
5 Parameter
S
Status word, source from
P509.
Actual values
The displayed value depicts
all Bus OUT Bit sources linked
with an "OR".
Data during parameter
transfer.
Actual value of master
function
P502 / P503.
Status word + Actual values to
PLC
S
217