NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 482 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P509 – Quell e Steuer wort [SK 1x0E, SK 2xxE] @ 2\mod_1346932164693_388.doc x @ 43032 @ @ 1
Control word source
P509
(Control word source)
0 ... 4
Selection of the interface via which the FI is controlled.
{ 0 }
0 =
1 =
2 =
3 =
4 =
NOTE: For details of the optional bus systems, please refer to the relevant supplementary bus manuals.
Pos : 483 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P509 – Quell e Steuer wort - Ergänz ung [SK 2xxE] @ 9\mod_1448293499605_388.doc x @ 265981 @ @ 1
As an alternative to setting the parameter, System Bus can also be selected with DIP switch
S1:3.
Pos : 484 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P510 – Quell e Soll werte [SK 1x0E, SK 2xxE] @ 2\mod_1346932165333_388.doc x @ 43056 @ @ 1
P510
Setpoints source
[-01]
[-02]
(Setpoints source)
0 ... 4
Selection of the setpoint source to be parameterised.
{ [-01] = 0 }
[-01] = Main setpoint source
{ [-02] = 0 }
Selection of the interface via which the FI receives the setpoint.
Pos : 485 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P511 – USS-Baudrate [SK 1x0E, SK 2xxE, SK 2xx-FD S] @ 2\mod_1346932165972_388.doc x @ 43080 @ @ 1
USS baud rate
P511
(USS baud rate)
0 ... 3
Setting of the transfer rate (transfer speed) via the RS485 interface. All bus participants must
have the same baud rate setting.
{ 3 }
0 =
1 =
Pos : 486 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
190
Control terminals or keyb. cont., "Control terminals or keyboard control" ** with the
SimpleBox (if P510=0), the ParameterBox or via BUS I/O bits.
Only control terminals *, the FI can only be controlled via the digital and analogue inputs
or via the bus I/O Bits.
USS *, the control signals (enable, rotation direction, etc.) are transferred via the RS485
interface, and the setpoint is transferred via the analogue input or the fixed frequencies.
System bus *, setting for actuation by master via a bus interface
System bus broadcast *, setting for actuation by a master drive in Master / Slave mode
(e.g. with synchronous applications)
*)
Keyboard control (SimpleBox, ParameterBox) is disabled, parameterisation is still
possible.
**) If communication is interrupted during keyboard control (timeout 0.5 sec), the FI will
block without an error message.
0 = Auto: The source of the setpoint is
automatically derived from the setting of
parameter P509.
1 = Only control terminals, digital and
analogue inputs control the frequency,
including fixed frequencies
4800 Baud
9600 Baud
-
www.nord.com
[-02] = Subsidiary setpoint source
2 = USS, see P509
3 = System bus, see P509
4 = System bus broadcast, see P509
2 =
19200 Baud
3 =
38400 Baud
S
S
S
BU 0200 en-3118

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents