NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 492 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P515 – CAN- Adr ess e_01 [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346932167813_388.doc x @ 43152 @ @ 1
P515
[-01]
CAN address
...
(CAN address (system bus))
[-03]
0 ... 255
Setting of the system bus address.
dec
{ all 32
}
[-01] = Slave address, Receive address for system bus
dec
or { all 20
}
[-02] = Broadcast slave address, system bus reception address (slave)
hex
[-03] = Master address, "Broadcast master address", transmission address for system bus
NOTE: If up to four FI are to be linked via the system bus, the addresses must be set as follows  FI 1 =
32, FI 2 = 34, FI 3 = 36, FI 4 = 38.
Pos : 493 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P515 – CAN- Adr ess e_02 [SK 1x0E, SK 2xxE] @ 17\mod_1490096962359_388.doc x @ 2336244 @ @ 1
The system bus addresses should be set via DIP switches (chapter 4.3.2.2).
Pos : 494 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P516 – Aus blendfrequenz 1 @ 0\mod_1328092606664_388.doc x @ 11249 @ @ 1
Skip frequency 1
P516
(Skip frequency 1)
0.0 ... 400.0 Hz
The output frequency around the frequency value (P517) set here is not shown.
{ 0.0 }
This range is transmitted with the set brake and acceleration ramp; it cannot be continuously
supplied to the output. Frequencies below the absolute minimum frequency should not be set.
0 = Skip frequency inactive
Pos : 495 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P517 – Aus blendbereic h 1 @ 0\mod_1328092662665_388.doc x @ 11272 @ @ 1
Skip freq. area 1
P517
(Skip frequency area 1)
0.0 ... 50.0 Hz
Skip range for the >Skip frequency 1< P516. This frequency value is added and subtracted from
the skip frequency.
{ 2.0 }
Skip frequency range 1: P516 - P517 ... P516 + P517
Pos : 496 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P518 – Aus blendfrequenz 2 @ 0\mod_1328092706493_388.doc x @ 11295 @ @ 1
Skip frequency 2
P518
(Skip frequency 2)
0.0 ... 400.0 Hz
The output frequency around the set frequency value (P519) is skipped.
{ 0.0 }
This range is transmitted with the set brake and acceleration ramp; it cannot be continuously
supplied to the output. Frequencies below the absolute minimum frequency should not be set.
0 = Skip frequency inactive
Pos : 497 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P519 – Aus blendbereic h 2 @ 0\mod_1328092748353_388.doc x @ 11318 @ @ 1
Skip freq. area 2
P519
(Skip frequency area 2)
0.0 ... 50.0 Hz
Skip range for the >Skip frequency 2< P518. This frequency value is added and subtracted from
the skip frequency.
{ 2.0 }
Skip frequency range 2: P518 - P519 ... P518 + P519
Pos : 498 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
192
(master)
S
S
P
S
P
S
P
S
P
BU 0200 en-3118