Encoder error
E013
13.1
Speed slip error
"Speed slip error"
13.2
Shut-down monitoring
13.5
Reserved
13.6
Reserved
Pos : 662 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/F ehl er E014 "res er viert" [SK 200E ... SK 5xxE] @ 2\mod_1347454273854_388.doc x @ 46776 @ @ 1
---
Reserved
E014
Pos : 663 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/F ehl er E015 [SK 180E ... SK 5xxE] @ 2\mod_1347454278051_388.doc x @ 46801 @ @ 1
---
Reserved
E015
Pos : 664 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/F ehl er E016 [SK 135E ... SK 5xxE, SK xxxE-FDS] @ 2\mod_1347454280625_388.doc x @ 46826 @ @ 1
16.0
Motor phase error
E016
16.1
Magnetisation current
monitoring
"Magnetisation current
monitoring"
Pos : 665 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/F ehl er E018 "res er viert" [SK 2xxE/SK 5xxE/SK 2xxE-FDS] @ 2\mod_1347454282777_388.doc x @ 46851 @ @ 1
18.0
Reserved
E018
Pos : 666 /Anleitungen/El ektr oni k/FU und Starter/6. M eldung en zum Betriebsz ustand/Stör meldung en (Auflistung)/F ehl er E019 [SK 180E/SK 2xxE/SK 5xxE/SK2xxE-FD S] @ 2\mod_1347454285788_388.doc x @ 46876 @ @ 1
19.0
Parameter identification
E019
"Parameter identification"
19.1
Star / Delta circuit incorrect
"Motor star / delta circuit
incorrect"
Pos : 667 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
6 Operating status messages
No signal from encoder
Check 5V sensor if present.
Check supply voltage of encoder.
The slip speed error limit was reached.
Increase setting in P327.
The slip error monitoring has triggered; the motor could not
follow the setpoint.
Check motor data P201-P209! (Important for the
current controller)
Check motor circuit.
In servo mode, check the encoder setting P300 and
check the following
Increase setting value for torque limit in P112.
Increase setting value for current limit in P536.
Check deceleration time P103 and extend if
necessary
Error message for POSICON  see supplementary
instructions
Error message for POSICON  see supplementary
instructions
Error message for POSICON  see supplementary
instructions
A motor phase is not connected.
Check P539
Check motor connection
Required exciting current not achieved at moment of switch-
on.
Check P539
Check motor connection
Error message for "Safe Pulse Block"  see supplementary
instructions
Automatic identification of the connected motor was
unsuccessful
Check motor connection
Check preset motor data (P201 ... P209)
PMSM – CFC Closed Loop Operation: Rotor position
of motor incorrect in relation to incremental encoder
Perform determination of rotor position (initial enable
after a "Mains on" only with motor stationary (P330)