Jog frequency
P113
(Jog frequency)
-400.0 ... 400.0 Hz
When using the SimpleBox or ParameterBox to control the FI, the jog frequency is the initial
value following successful enabling.
{ 0.0 }
Alternatively, when control is via the control terminals, the jog frequency can be activated via one
of the digital inputs.
The setting of the jog frequency can be done directly via this parameter or, if the FI is enabled via
the keyboard, by pressing the OK key. In this case, the actual output frequency is set in
parameter P113 and is then available for the next start.
NOTE:
analogue setpoints, are generally added with the correct sign. The set maximum frequency
(P105) cannot be exceeded and the minimum frequency (P104) cannot be undershot.
Pos : 325 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P100- P199/Parameter P114 – Lüftzei t Br ems e @ 0\mod_1327587947470_388.doc x @ 7815 @ @ 1
Brake delay off
P114
(Brake release time)
0 ... 2.50 s
Electromagnetic brakes have a delayed reaction time during ventilation, which depends on
physical factors. This can lead to the motor running while the brake is still applied, which will
{ 0.00 }
cause the inverter to switch off with an overcurrent report.
This release time can be taken into account in parameter P114 (Brake control).
During the adjustable ventilation time, the FI supplies the set absolute minimum frequency (P505)
thus preventing movement against the brake.
See also the parameter >Brake reaction time< P107 (setting example).
NOTE:
If the brake ventilation time is set to "0", then P107 is the brake ventilation and reaction time.
Pos : 326 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P100- P199/Parameter P120 – Opti ons über wac hung [SK 1x0E, SK 2xxE, SK 54xE, SK 2xxE-FDS] @ 2\mod_1346931600646_388.doc x @ 42230 @ @ 1
P120
[-01]
Option monitoring
...
(Option monitoring)
[-04]
Monitoring of communication at system bus level (in case of error: error message 10.9)
0 ... 2
{ 1 }
Array levels:
[-01] = Extension 1 (BUS unit)
[-02] = Extension 2 (second I/O unit)
Setting values
0 =
1 =
2 =
Note: If error messages which are detected by the optional module (e.g. errors at field bus level)
are not to result in a shut-down of the drive electronics, parameter (P513) must also be set to the
value {-0,1}.
Pos : 327 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
Specified setpoints via the control terminals, e.g. jog frequency, fixed frequencies or
Monitoring OFF
Auto, communication is only monitored if an existing communication is interrupted. If a
module which was previously present is not found after switching on the mains, this does
not result in an error
Monitoring only becomes active when an extension starts communication with the FI.
Monitoring active immediately "Monitoring active immediately" , the FI starts monitoring
the corresponding module immediately after the mains are switched on. If the module is
not detected on switch-on, the FI remains in the status "not ready for switch-on" for 5
seconds and then triggers an error message.
5 Parameter
S
S
S
[-03] = Extension 3 (first I/O unit)
[-04] = Extension 4 (reserved)
P
P
145