Pos : 559 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P703 – Strom l etz te Störung 1...5 @ 0\mod_1328170627489_388.doc x @ 12387 @ @ 1
P703
[-01]
Current last error
...
(Last current error 1...5)
[-05]
0.0 ... 999.9 A
This parameter stores the output current that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
Pos : 560 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P704 – Spannung letzte Störung 1...5 @ 0\mod_1328170671391_388.doc x @ 12410 @ @ 1
P704
[-01]
Volt. last error
...
(Last voltage error 1...5)
[-05]
0 ... 600 V AC
This parameter stores the output voltage that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
Pos : 561 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P705 – Z wisc henkreis spannung l etz te Stör ung 1...5 @ 0\mod_1328170720639_388.doc x @ 12433 @ @ 1
P705
[-01]
Last link circuit error
...
(Last link circuit error 1...5)
[-05]
0 ... 1000 V DC
This parameter stores the link voltage that was being delivered at the time the error occurred. The
values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
Pos : 562 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P706 – Parametersatz l etzte Störung 1...5 @ 0\mod_1328170810570_388.doc x @ 12456 @ @ 1
P706
[-01]
P set last error
...
(Parameter set, last error 1... 5)
[-05]
0 ... 3
This parameter stores the parameter set code that was active when the error occurred. Data for
the previous 5 faults are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
Pos : 563 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P707 – Softwar e-Version/-Revi sion @ 0\mod_1328171743458_388.doc x @ 12479 @ @ 1
P707
[-01]
Software-Version
...
(Software version/ revision)
[-03]
0.0 ... 9999.9
This parameter shows the software and revision
numbers in the FI. This can be significant when
different FIs are assigned the same settings.
Array 03 provides information about any special
versions of the hardware or software A zero
stands for the standard version.
Pos : 564 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
5 Parameter
S
S
S
S
... [-01] =
Version number (Vx.x)
... [-02] =
Revision number (Rx)
... [-03] =
Special version of
hardware/software (0.0)
209