NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 538 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Parameter P553 – PLC Soll werte [SK 1x0E, SK 2xxE] @ 9\mod_1448356543219_388.doc x @ 266158 @ @ 1
P553
[-01]
PLC setpoints
...
(PLC setpoints)
[-05]
0 ... 57
The PLC setpoints are assigned with a function in this parameter. The settings only apply for
main setpoints and with active PLC actuation ((P350) = "On") and ((P351) = "0" or "1").
all = { 0 }
[-01] = Bus setpoint value 1
Possible values which can be set:
10 = Servo mode torque
11 = Torque precontrol
12 = Reserved
13 = Multiplication
14 = Process controller actual value
15 = Process controller setpoint
16 = Process controller lead
#
Pos : 539 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
204
0 = Off
1 = Setpoint frequency
2 = Torque current limit
3 = Actual frequency PID
4 = Frequency addition
5 = Frequency subtraction
6 = Current limit
7 = Maximum frequency
8 = Actual PID frequency limited
9 = Actual PID frequency monitored
S
...
[-05] = Bus setpoint 5
17 = BusIO In Bits 0-7
18 = Curve travel calculator
19 = Set relays
20 = Set analogue out
21 = Setpoint position Low word
22 = Setpoint pos. HighWord
23 = Setpoint pos. Inc.LowWord
24 = Target pos.Inc.HighWord
46 = Torque process controller setpoint
47 = Gearing ratio
48 = Motor temperature
49 = Ramp time
53 = d-correction F process
54 = d-correction Torque
55 = d-correction F+Torque
56 = Acceleration time
57 = Deceleration time
BU 0200 en-3118