Nom. val. process ctrl.
P412
(Nominal value process controller)
-10.0 ... 10.0 V
Fixed specification of a setpoint for the process controller that will only occasionally be altered.
{ 5.0 }
Only with P400 = 14 ... 16 (process controller) 8.2 "Process controller".
Pos : 436 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P413 – P- Anteil PI-Regl er [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931799733_388.doc x @ 42503 @ @ 1
P-component of PI-controller
P413
(P-component PI-controller)
0.0 ... 400.0 %
This parameter is only effective when the function PI controller actual frequency is selected.
{ 10.0 }
The P-component of the PI controller determines the frequency jump if there is a control deviation
based on the control difference.
E.g.: At a setting of P413 = 10% and a rule difference of 50%, 5% is added to the actual setpoint.
Pos : 437 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P414 – I-Anteil PI-Regler [SK 1x0E, SK 2xxE, SK 2xxE-FD S] @ 2\mod_1346931800404_388.doc x @ 42527 @ @ 1
I-component PI-controller
P414
(I-component of PI-controller)
0.0 ... 3,000.0 %/s
This parameter is only effective when the function PI controller actual frequency is selected.
{ 10.0 }
The I-component of the PI controller determines the frequency change, dependent on time.
Note:
(Reason: better setting ability with small I-proportions).
Pos : 438 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P415 – Gr enz e Proz eßr egler [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931801199_388.doc x @ 42551 @ @ 1
Process controller limit
P415
(Control limit of process controller)
0 ... 400.0 %
This parameter is only effective when the function PI process controller is selected. This
determines the control limit (%) after the PI controller (please see chapter 8.2 "Process
{ 10.0 }
controller").
Pos : 439 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P416 – Rampenz eit PI- Soll wert [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 2\mod_1346931801870_388.doc x @ 42575 @ @ 1
Ramp time PI setpoint
P416
(Ramp time PI setpoint value)
0.00 ... 99.99 sec
This parameter is only effective when the function PI process controller is selected.
{ 2.00 }
Ramp for PI setpoint
Pos : 440 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P400- P499/Parameter P417 – Offs et Anal ogausgang [SK 1x0E, SK 2xxE, SK 2xxE-FD S] @ 2\mod_1346931802525_388.doc x @ 42599 @ @ 1
P417
[-01]
Offset analogue output
...
(Offset analogue output)
[-02]
-10.0 ... 10.0 V
[-01] = First IOE, AOUT of the first I/O extension (SK xU4-IOE)
{ all 0.0 }
[-02] = Second IOE, AOUT of the second I/O extension (SK xU4-IOE)
only with
In the analogue output function an offset can be entered to simplify the processing of the
SK CU4-IOE or
analogue signal in other equipment.
SK TU4-IOE
If the analogue output has been programmed with a digital function, then the difference between
the switch-on point and the switch-off point can be set in this parameter (hysteresis).
Pos : 441 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
In contrast to other NORD series, parameter P414 is smaller by a factor of 100