NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 374 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P300- P399/Parameter P301 – Drehgeber Auflösung @ 0\mod_1327591605104_388.doc x @ 8511 @ @ 1
Rotary encoder res.
P301
(Rotary encoder resolution)
0 ... 17
Input of the pulse-count per rotation of the connected encoder.
{ 6 }
If the encoder rotation direction is not the same as the FI, (depending on installation and wiring),
this can be compensated for by selecting the corresponding negative pulse numbers 8...16.
0 = 500 pulses
1 = 512 pulses
2 = 1000 pulses
3 = 1024 pulses
4 = 2000 pulses
5 = 2048 pulses
6 = 4096 pulses
7 = 5000 pulses
17 = 8192 pulses
NOTE:
(P301) is also significant for position control via incremental encoders. If an incremental encoder
is used for positioning (P604=1), the setting of the pulse number is made here. (Please refer to
POSICON Supplementary Manual)
Pos : 375 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
156
8 = -500 pulses
9 = -512 pulses
10 = -1000 pulses
11 = -1024 pulses
12 = -2000 pulses
13 = -2048 pulses
14 = -4096 pulses
15 = -5000 pulses
16 = -8192 pulses
BU 0200 en-3118