NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 571 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P711 – Zustand Digital e Ausgäng e [SK 2xxE] @ 2\mod_1346932206390_388.doc x @ 43536 @ @ 1
State of relays
P711
(state of digital outputs)
00000 ... 11111
Indicates the actual status of the digital outputs of the frequency inverter.
(bin)
or
Bit 0 = Digital output 1
Bit 1 = Mechanical brake
00 ... FF
(hex)
Bit 2 = Digital output 2
Bit 3 = reserved
Pos : 572 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P711 – Zustand Digital e Ausgäng e_T eil2/2 [SK 1x0E, SK 2xxE, SK 2xxE-FDS] @ 9\mod_1448448278913_388.doc x @ 266811 @ @ 1
Minimum value
Maximum value
SimpleBox: The binary bits are converted to a hexadecimal value and displayed.
ParameterBox: The bits are displayed increasing from right to left (binary).
Pos : 573 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P714 – Betriebs dauer @ 0\mod_1328172684685_388.doc x @ 12663 @ @ 1
Operating time
P714
(Operating time)
0.10 ... ___ h
This parameter shows the time for which the FI was connected to the mains and was ready for
operation.
Pos : 574 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P715 – Freigabedauer @ 0\mod_1328172731474_388.doc x @ 12686 @ @ 1
Running time
P715
(Enablement time)
0.00 ... ___ h
This parameter shows the time for which the FI was enabled and supplied current to the output.
Pos : 575 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P716 – Aktuelle Frequenz @ 0\mod_1328172775215_388.doc x @ 12709 @ @ 1
Current frequency
P716
(Actual frequency)
-400.0 ... 400.0 Hz
Displays the actual output frequency.
Pos : 576 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P717 – Aktuelle Drehz ahl @ 0\mod_1328172889966_388.doc x @ 12732 @ @ 1
Current speed
P717
(Actual rotation speed)
-9999 ... 9999 rpm
Displays the actual motor speed calculated by the FI.
Pos : 577 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Parameter P718 – Aktuelle Sollfreq uenz @ 0\mod_1328172931732_388.doc x @ 12755 @ @ 1
Present Actual setpoint
P718
[-01]
frequency
...
[-03]
(Actual setpoint frequency)
-400.0 ... 400.0 Hz
Displays the frequency specified by the setpoint
(please see chapter 8.1 "Setpoint processing").
[-01] = Actual setpoint frequency from the setpoint source
[-02] = Actual setpoint frequency after processing in the FI status machine
[-03] = Actual setpoint frequency after frequency ramp
Pos : 578 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
212
Bit 4 = Digital output 1, IO extension 1
Bit 5 = Digital output 2, IO extension 1
Bit 6 = Digital output 1, IO extension 2
Bit 7 = Digital output 2, IO extension 2
Bits 7-4
Bits 3-0
0000
0
1111
F
0000
Binary
0
hex
1111
Binary
F
hex