Nominal motor frequency
P201
(Nominal motor frequency)
10.0 ... 399.9 Hz
The motor nominal frequency determines the V/f break point at which the FI supplies the nominal
voltage (P204) at the output.
{ see information }
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos : 333 /Anleitungen/El ektr oni k/FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P200- P299/Parameter P202 – Motor N enndrehz ahl @ 0\mod_1327588441470_388.doc x @ 7907 @ @ 1
Nominal motor speed
P202
(Nominal motor speed)
150 ... 24000 rpm
The nominal motor speed is important for the correct calculation and control of the motor slip and
the speed display (P001 = 1).
{ see information }
The default setting is dependent upon the FI nominal power and the setting in P200.
Pos : 334 /Allgemein/Allgemeingültig e Module/---------Seitenumbr uc h kompakt --------- @ 13\mod_1476369695906_0.doc x @ 2265495 @ @ 1
BU 0200 en-3118
No change
No motor: In this setting, the FI operates without current control, slip compensation and
pre-magnetising time, and is therefore not recommended for motor applications. Possible
applications are induction furnaces or other applications with coils and transformers. The
following motor data is set here: 50.0 Hz / 1500 rpm / 15.0 A / 400 V / 0.00 kW / cos