Ci (Cluster Id); Rf Interfacing Commands; Tx Power Level) - Digi XBee 3 ZigBee User Manual

Rf module
Table of Contents

Advertisement

AT commands
0xE8 - Digi data endpoint
n
0xE6 - Digi device object endpoint
n
0xE5 - Secure Session Server endpoint
n
0xE4 - Secure Session Client endpoint
n
0xE3 - Secure Session SRP authentication endpoint
n
Parameter range
0 - 0xFF
Default
0xE8

CI (Cluster ID)

Sets or displays the application layer Cluster ID value used for data transmissions.
This command only affects outgoing transmissions in transparent mode (AP = 0).
0x11 is a transparent data cluster ID.
0x12 is a loopback cluster ID.
Parameter range
0 - 0xFFFF
Default
0x11 (Transparent data cluster ID)

RF interfacing commands

The following AT commands affect the RF interface of the device.
PL (TX Power Level)
Sets or displays the power level at which the device transmits conducted power.
Note
If operating on channel 26 (CH = 0x1A), output power will be capped and cannot exceed 8 dBm
regardless of the PL setting.
Parameter range
0 - 4
Setting
XBee 3-PRO
0
-5 dBm
1
+3 dBm
2
+8 dBm
3
+15 dBm
4
+19 dBm
Digi XBee® 3 Zigbee® RF Module
XBee 3 non-PRO
-5 dBm
-1 dBm
+2 dBm
+5 dBm
+8 dBm
RF interfacing commands
196

Advertisement

Table of Contents
loading

Table of Contents