Digi XBee 3 ZigBee User Manual page 308

Rf module
Table of Contents

Advertisement

Status
Transparent
code
mode string
Description
Reject ID
Not an association candidate because
0x06
configured pan ID does not match that given
in the beacon response.
Reject NJ
0x07
Not an association candidate because it is not
allowing joins.
JV/NW with search option (DO80) has found a
0x08
panID Match
matching network.
Reject
JV/NW with search option (DO80) candidate
0x09
LQIRSSI
rejected because this beacon response is
weaker than an earlier beacon response.
0x0A
Beacon Saved This beacon response is a suitable candidate
for an association request.
AI
AI value has changed.
0x0B
NJ setting (Permit Join Duration) has changed value(1)
0x0C
Permit Join
0x0D
Scanning
Active scanning has begun.
0x0E
Scan Error
An error occurred during active scan.
Status data
Description
panId(2)
16 bit PAN Identifier for network
radioChannel
channel number ranging from 11 to 26 (0x0B to 0x1A)
(1)
radioTxPower
low level signed byte value for transmit power, values range
(1)
from 0xC9 to 0x05 inclusive
panid(2)
16 bit PAN Identifier for network
extendedPanId
64 bit PAN Identifier for network
(8)
See a description of
AIStatusCode
(1)
See a description of the
A 32 bit value driven by the SC setting where bit positions 11
ChannelMask
through 26 show which channels are enabled for the
(4)
upcoming Active Scan. See a description of
Channels).
StatusCode(1)
AI (Association Indication)
NJ (Node Join Time)
command.
SC (Scan